Product Description
Amidst the distinguished names, we are affianced in offering an extensive range of CO2 Flooding System for our clients. The provided system is manufactured in adherence with international quality standards using the finest quality raw materials and progressive techniques. The offered system is ideal for quickly extinguishing the fire by inhibiting the supply of oxygen by employing carbon dioxide gas. Moreover, this CO2 Flooding System is available with us in various specifications at negotiable prices.
Features of Carbon Dioxide Total Flooding System
- Excellent sensitivity
- Longer operational life
- Hassle-free operation
- Easy automation and installation
DetailsOur Carbon Dioxide Total Flooding System is a precisely engineered system that is accessible in three utilization configurations: local application or hand-hose line, total flooding (for free areas). System incorporates a control unit, agent storage cylinders, detectors, piping and discharge hooters. Gaseous carbon dioxide quickly subdues fire by a sequence of cooling and oxygen expatriation. Discharge continuance and agent flow rates are custom-made for every individualized application.
Technical Specifications:- Cut down the oxygen content of the atmosphere to a location where burning becomes infeasible.
- Hardware to adapt any application and system variety.
- Provided in assorted capacity cylinders as per the demand of the client.
- Directional valve system alternatives, lockout circuits and lockout valves.
Features:- Evidenced quality and dependability.
- A cut-rate and easy-to-access agent is accessible when refill becomes essential.
- Wide compasses of well-tried safety, endangerment protection.
Listings/Approvals:
FM
UL
Technical Specifications
| Usage/Application | Electrical Room, Chemical Room, Unmanned area |
| Condition | New |
| Cylinder Height (mm) | As per design |
| Design | On request |
| Extinguishing Agent | Carbon Di Oxide |
| Fire Class | BC |
| Certification | CE, VDS, |
| Fire Suppression Type | Total Flooding |
Comprehensive Protection and Fast ResponseEngineered to tackle flammable liquid (Class B) and electrical (Class C) fires, the Carbon Dioxide Total Flooding System disperses CO2 gas rapidly, suppressing fire in seconds without leaving residue. Its quick suppression ability is vital for environments where downtime or equipment damage must be minimized.
Flexible, Customizable, and Durable DesignWith high-strength seamless steel cylinders (capacities from 5 to 200 kg) and stainless steel nozzles, the system accommodates varied project requirements. It offers pre-engineered or engineered configurations, customizable for coverage areas up to 500 square meters, making it suitable for diverse industrial and commercial facilities.
Intuitive Operation and Integrated Safety FeaturesThe system includes audible and visual alarms, pressure relief valves, lockout provisions, and real-time system status indicators. Detection via smoke and heat sensors, alongside configurable actuation delay and both manual and automatic controls, ensures rapid, reliable activation while maintaining workplace safety.
FAQs of Carbon Dioxide Total Flooding System:
Q: How does the Carbon Dioxide Total Flooding System suppress fires?
A: This system uses high-purity CO2 gas, which is rapidly discharged (within 1060 seconds) through stainless steel nozzles to flood the protected area. The carbon dioxide reduces oxygen levels, swiftly extinguishing flammable liquid and electrical fires (Class B & C) without damaging sensitive equipment or leaving residue.
Q: What maintenance is required to keep the system operational and safe?
A: Regular maintenance involves inspecting the pressure gauge, verifying visual indicators, checking the integrity of cylinders and nozzles, and ensuring alarm and detection systems are functional. Refilling of CO2 cylinders can be performed on-site or off-site. Following NFPA 12 and IS:6382 standards helps maintain system reliability and extends operational life to up to 10 years.
Q: When should the actuation delay be configured, and why is it important?
A: The actuation delay, adjustable from 0 to 60 seconds, should be set during commissioning based on occupancy patterns and safety protocols in your facility. This brief delay ensures personnel have time to evacuate before CO2 release, enhancing overall site safety during activation.
Q: Where can this total flooding CO2 system be installed?
A: Its suitable for industrial environments, data centers, electrical rooms, and chemical storage facilitiesanywhere rapid, residue-free fire suppression is crucial. The fixed, floor- or wall-mounted cylinders and networked detection/activation components integrate seamlessly into both new and existing buildings.
Q: What are the benefits of using CO2 as a fire suppression agent?
A: CO2 is a clean, non-conductive gas that leaves no residue, making it ideal for protecting sensitive electronics and critical infrastructure. Its fast-acting suppression minimizes damage and downtime, and its effective for hazards involving flammable liquids and electrical equipment.
Q: How is the system refilled after a discharge?
A: After activation, CO2 cylinders can be refilled either on-site or sent off-site, depending on service availability and system design. Certified professionals will ensure cylinders are properly recharged and the system is ready for redeployment.
Q: What process should be followed for safe system operation and response?
A: Upon fire detection, smoke and heat sensors trigger system alarms and initiate automatic or manual discharge, depending on user preference. Staff should evacuate promptly when alarms sound. The systems safety featurespressure relief valve, lockout provisions, and status indicatorshelp ensure safe maintenance and operation at all times.